wklejto.pl

Dodane przez: ~Anonim (2013-10-17 21:29) -> text
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
39.
40.
41.
42.
43.
44.
45.
46.
47.
48.
49.
50.
51.
52.
53.
54.
55.
56.
57.
58.
59.
60.
61.
62.
63.
64.
65.
66.
67.
68.
69.
70.
71.
72.
73.
74.
75.
76.
77.
78.
79.
80.
81.
82.
83.
84.
85.
86.
87.
88.
89.
90.
91.
92.
93.
94.
95.
96.
97.
98.
99.
100.
101.
102.
103.
104.
105.
106.
107.
108.
109.
110.
111.
112.
113.
114.
115.
116.
117.
118.
119.
120.
121.
122.
123.
124.
125.
126.
127.
128.
129.
130.
131.
132.
133.
134.
135.
136.
137.
138.
139.
140.
141.
142.
143.
144.
145.
146.
147.
148.
149.
150.
151.
152.
153.
154.
155.
156.
157.
158.
159.
160.
161.
162.
163.
164.
165.
166.
167.
168.
169.
170.
171.
172.
173.
174.
175.
176.
177.
178.
179.
180.
181.
182.
183.
184.
185.
186.
187.
188.
189.
190.
191.
192.
193.
194.
195.
196.
197.
198.
smartctl 6.1 2013-03-16 r3800 [i686-linux-3.10.9-lesslinux-000] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
 
=== START OF INFORMATION SECTION ===
Model Family:     Toshiba 2.5" HDD MK..52GSX
Device Model:     TOSHIBA MK3252GSX
Serial Number:    98U9P66AT
LU WWN Device Id: 5 000039 142588c3c
Firmware Version: LV010M
User Capacity:    320,072,933,376 bytes [320 GB]
Sector Size:      512 bytes logical/physical
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS (minor revision not indicated)
SATA Version is:  SATA 2.6, 1.5 Gb/s
Local Time is:    Sat Oct 12 07:33:13 2013 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
 
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
 
General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status:      ( 112) The previous self-test completed having
the read element of the test failed.
Total time to complete Offline 
data collection: (  120) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine 
recommended polling time: (   2) minutes.
Extended self-test routine
recommended polling time: ( 136) minutes.
SCT capabilities:        (0x0039)       SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
 
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000b   100   100   050    Pre-fail  Always       -       0
  2 Throughput_Performance  0x0005   100   100   050    Pre-fail  Offline      -       0
  3 Spin_Up_Time            0x0027   100   100   001    Pre-fail  Always       -       1552
  4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       -       7448
  5 Reallocated_Sector_Ct   0x0033   100   100   050    Pre-fail  Always       -       46
  7 Seek_Error_Rate         0x000b   100   100   050    Pre-fail  Always       -       0
  8 Seek_Time_Performance   0x0005   100   100   050    Pre-fail  Offline      -       0
  9 Power_On_Hours          0x0032   047   047   000    Old_age   Always       -       21571
10 Spin_Retry_Count        0x0033   247   100   030    Pre-fail  Always       -       0
12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       5891
191 G-Sense_Error_Rate      0x0032   100   100   000    Old_age   Always       -       2847
192 Power-Off_Retract_Count 0x0032   097   097   000    Old_age   Always       -       1772
193 Load_Cycle_Count        0x0032   074   074   000    Old_age   Always       -       263037
194 Temperature_Celsius     0x0022   100   100   000    Old_age   Always       -       37 (0 55 0 0 0)
196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       -       43
197 Current_Pending_Sector  0x0032   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0030   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x0032   200   200   000    Old_age   Always       -       6
220 Disk_Shift              0x0002   100   100   000    Old_age   Always       -       8230
222 Loaded_Hours            0x0032   051   051   000    Old_age   Always       -       19763
223 Load_Retry_Count        0x0032   100   100   000    Old_age   Always       -       0
224 Load_Friction           0x0022   100   100   000    Old_age   Always       -       0
226 Load-in_Time            0x0026   100   100   000    Old_age   Always       -       340
240 Head_Flying_Hours       0x0001   100   100   001    Pre-fail  Offline      -       0
 
SMART Error Log Version: 1
ATA Error Count: 2172 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
 
Error 2172 occurred at disk power-on lifetime: 21531 hours (897 days + 3 hours)
  When the command that caused the error occurred, the device was active or idle.
 
  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 2f 3d 2f e0  Error: UNC at LBA = 0x002f3d2f = 3095855
 
  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  42 d8 00 3f 3c 2f e0 00      00:07:28.517  READ VERIFY SECTOR(S) EXT
  42 d8 00 3f 3a 2f e0 00      00:07:28.513  READ VERIFY SECTOR(S) EXT
  42 d8 00 3f 38 2f e0 00      00:07:28.510  READ VERIFY SECTOR(S) EXT
  42 d8 00 3f 36 2f e0 00      00:07:28.504  READ VERIFY SECTOR(S) EXT
  42 d8 00 3f 34 2f e0 00      00:07:28.490  READ VERIFY SECTOR(S) EXT
 
Error 2171 occurred at disk power-on lifetime: 21524 hours (896 days + 20 hours)
  When the command that caused the error occurred, the device was active or idle.
 
  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 31 da aa e0  Error: UNC at LBA = 0x00aada31 = 11196977
 
  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  42 d8 00 00 da aa e0 00      00:06:09.139  READ VERIFY SECTOR(S) EXT
  29 d8 01 00 00 00 e0 00      00:06:09.096  READ MULTIPLE EXT
  42 d8 00 00 da aa e0 00      00:06:04.973  READ VERIFY SECTOR(S) EXT
  42 d8 00 00 d8 aa e0 00      00:06:04.970  READ VERIFY SECTOR(S) EXT
  42 d8 00 00 d6 aa e0 00      00:06:04.965  READ VERIFY SECTOR(S) EXT
 
Error 2170 occurred at disk power-on lifetime: 21524 hours (896 days + 20 hours)
  When the command that caused the error occurred, the device was active or idle.
 
  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 31 da aa e0  Error: UNC at LBA = 0x00aada31 = 11196977
 
  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  42 d8 00 00 da aa e0 00      00:06:04.973  READ VERIFY SECTOR(S) EXT
  42 d8 00 00 d8 aa e0 00      00:06:04.970  READ VERIFY SECTOR(S) EXT
  42 d8 00 00 d6 aa e0 00      00:06:04.965  READ VERIFY SECTOR(S) EXT
  42 d8 00 00 d4 aa e0 00      00:06:04.961  READ VERIFY SECTOR(S) EXT
  42 d8 00 00 d2 aa e0 00      00:06:04.958  READ VERIFY SECTOR(S) EXT
 
Error 2169 occurred at disk power-on lifetime: 21512 hours (896 days + 8 hours)
  When the command that caused the error occurred, the device was active or idle.
 
  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 1b a6 d2 09 e0  Error: UNC at LBA = 0x0009d2a6 = 643750
 
  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  29 00 3b 7c d2 09 e0 00      00:30:26.622  READ MULTIPLE EXT
  29 00 40 14 fe 0b e0 00      00:30:26.595  READ MULTIPLE EXT
  29 00 08 c4 27 0a e0 00      00:30:26.567  READ MULTIPLE EXT
  29 00 38 80 e8 09 e0 00      00:30:26.550  READ MULTIPLE EXT
  29 00 40 00 ca 0b e0 00      00:30:26.512  READ MULTIPLE EXT
 
Error 2168 occurred at disk power-on lifetime: 21508 hours (896 days + 4 hours)
  When the command that caused the error occurred, the device was active or idle.
 
  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 01 9f 96 86 e0  Error: ICRC, ABRT 1 sectors at LBA = 0x0086969f = 8820383
 
  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 40 60 96 86 e0 00      00:02:46.489  READ DMA EXT
  25 00 40 da a2 cc e0 00      00:02:46.468  READ DMA EXT
  25 00 08 f8 ea b2 e0 00      00:02:46.453  READ DMA EXT
  25 00 3c c3 c2 69 e0 00      00:02:46.453  READ DMA EXT
  25 00 40 20 96 86 e0 00      00:02:46.452  READ DMA EXT
 
SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Completed: read failure       00%     21570         0
# 2  Short offline       Completed without error       00%     21564         -
# 3  Short offline       Aborted by host               40%     19095         -
# 4  Short offline       Completed without error       00%     19095         -
 
SMART Selective self-test log data structure revision number 1
SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
Wygenerowano w 0.035s, przy pomocy GeSHi 1.0.8
'
Podziel się na Facebook Podziel się na BLIP Podziel się na Twitter Podziel się na Buzz Podziel się na Flaker Dodaj zakładkę Google Podziel się na Delicious Wykop to!

Nowy Komentarz:

Komentarze:

Brak Komentarzy!